Code No. P2196:
Proportional Oxygen Sensor Signal Low
TROUBLE JUDGMENT
- Oxygen concentration too low at full load
PROBABLE CAUSES
- Failed throttle valve control motor
- Failed proportional oxygen sensor
- Failed electrical harness in proportional oxygen sensor circuit (Refer to Symptom
Procedure - Proportional Oxygen Sensor System
)