SERVICE SPECIFICATIONS


Item
Standard value
Limit
Variable induction control solenoid valve coil resistance (at 20°C) <6B3> Ω
29 - 35
-
Intake manifold distortion of the installation surface mm
6B3
0.15 or less
0.20
Exhaust manifold distortion of the installation surface mm
4B1
-
0.70
6B3
0.7 or less
0.5
Turbocharger supercharging pressure <4HN> kPa
110 - 160
-