STARTER RELAY CONTINUITY CHECK




Battery voltage
Terminal No. to be connected to tester
Continuity test results
Not applied
3 - 4
Open circuit
Connect terminal No.1 to battery (-) terminal.
Connect terminal No.2 to battery (+) terminal.
3 - 4
Continuity (less than 2 Ω)