Code No. P0705: Malfunction of Inhibitor Switch



















DIAGNOSTIC FUNCTION




JUDGMENT CRITERIA



  • Does not detect the inhibitor switch input signal for two seconds.
  • CVT-ECU detects the multiple inputs from the inhibitor switch for five seconds.

PROBABLE CAUSES



  • Malfunction of the inhibitor switch
  • Improper adjustment of transmission control cable
  • Damaged wiring harness and connectors
  • Malfunction of CVT-ECU

DIAGNOSTIC PROCEDURE


STEP 1. M.U.T.-III data list


Item 49: Inhibitor SW
Check that the service data changes when the selector lever is moved to all ranges.
OK: The service data changes in response to the selector lever operation.

Q. Is the check result normal?

Intermittent malfunction
Go to Step 2.

STEP 2. Check the following connector:



  • B-121 Inhibitor switch connector
  • C-135 CVT-ECU connector
Check the terminals for a contact status problem and internal short circuit.

Q. Is the check result normal?

Go to Step 3.
Repair the defective connector.

STEP 3. Check for open circuit in wiring harness between the ETACS-ECU connector and the inhibitor switch connector


Between the C-313 ETACS-ECU connector (terminal No. 4) and the B-121 inhibitor switch connector (terminal No. 3)
note Prior to the wiring harness inspection, check the intermediate connectors C-131 and A-13, and repair that if necessary.

Q. Is the check result normal?

Go to Step 4.
Repair the wiring harness.

STEP 4. Check for open circuit in the wiring harness between the inhibitor switch connector and the CVT-ECU connector



  • Between B-121 inhibitor switch connector (terminal No. 2) and C-135 CVT-ECU connector (terminal No. 32)
  • Between B-121 inhibitor switch connector (terminal No. 5) and C-135 CVT-ECU connector (terminal No. 45)
  • Between B-121 inhibitor switch connector (terminal No. 8) and C-135 CVT-ECU connector (terminal No. 34)
  • Between B-121 inhibitor switch connector (terminal No. 9) and C-135 CVT-ECU connector (terminal No. 33)

Q. Is the check result normal?

Go to Step 5.
Repair the wiring harness.

STEP 5. Inhibitor switch and control cable adjustment


Refer to .

Q. Is the check result normal?

Go to Step 6.
Adjust the inhibitor switch and control cable.

STEP 6. Inhibitor switch continuity check


Refer to .

Q. Is the check result normal?

Go to Step 7.
Replace the inhibitor switch.

STEP 7. Symptom recheck after erasing diagnosis code


Q. Is the check result normal?

Intermittent malfunction
Replace CVT-ECU.