Code No. P1612: Starter relay for Auto start
OPERATION
- Power for starter drive is supplied from the battery to the starter relay connector terminal.
- At the auto start, battery voltage is supplied to the starter relay coil connector terminal from the AS&G-ECU connector terminal STR.
- When the starter relay is turned "ON", battery voltage is supplied to the starter from the starter relay connector terminal.
FUNCTION
- The AS&G-ECU turns "ON" the starter relay at the auto start. This, in turn, supplies battery voltage to the starter.
TROUBLE JUDGMENT
Check Condition
- More than 2 seconds have passed since the ignition is switched "ON" or more than 2 seconds have passed since engine starting sequence was completed.
- Battery voltage is 11 V or more and 16 V or less.
- Not in auto start.
- he starter relay (for auto start) terminal monitor voltage is 4.5 V or more for 2 seconds.
FAIL-SAFE AND BACKUP FUNCTION
- In the normal operation, the auto stop is prohibited.
- If the malfunction is detected during the auto stop, the auto start is prohibited.
PROBABLE CAUSES
- Open/short circuit or damage in starter relay (auto start) circuit or loose connector contact
- Failed AS&G-ECU
DIAGNOSIS PROCEDURE |
STEP 1. Check of short circuit to power supply, short to earth, open circuit and harness damage in STR line between AS&G-ECU connector and starter relay connector. |
Q.
Is the check result normal?
|
Go to Step 2. |
|
Repair the damaged harness wire. |
|
STEP 2. M.U.T.-III diagnosis code |
|
Q.
Is the diagnosis code set?
|
Replace the AS&G-ECU. |
|
Intermittent malfunction (Refer to GROUP 00 - How to Use Troubleshooting/Inspection Service Points - How to Cope with Intermittent Malfunctions ). |
|

Repair the damaged harness wire.