Code No. P1796: Idle-N control function failure
DIAGNOSIS CODE SET CONDITIONS
- With the idle-N control, the status that the "actual slip speed - target
slip speed" is faster than 300 r/min continues for 10 seconds.
- When approx. 1 second has elapsed after A/T-ECU started, the failure signal of longitudinal
G-sensor is detected for 5 seconds.
PROBABLE CAUSES
- Malfunction of the CAN circuit
- Malfunction of the P0753: low clutch linear solenoid valve system
- Malfunction of the P0731: 1st gear incorrect ratio
- Malfunction of the A/T-ECU
DIAGNOSIS PROCEDURE |
STEP 1. M.U.T.-III CAN bus diagnostics. |
| Use M.U.T.-III to perform the CAN bus diagnosis. |
Q.
Is the check result normal?
|
Go to Step 2. |
|
Repair the CAN bus line (Refer to GROUP 54C - Troubleshooting ). |
|
STEP 2. Check the diagnosis code. |
Check the ASC diagnosis code. (Refer to GROUP 35C - Troubleshooting ). |
Q.
Is the diagnosis code set?
|
Check and repair the relevant diagnosis code system. |
|
Go to Step 3. |
|
STEP 3. Perform the troubleshooting for diagnosis code No. P0753: low clutch linear solenoid valve and diagnosis code No. P0731: 1st gear incorrect ratio. |
| Check whether the diagnosis code is reset. |
Q.
Is diagnosis code No.P1796 set?
|
Replace the A/T-ECU. |
|
This diagnosis is complete. |
|

Repair the CAN bus line (Refer to GROUP 54C - Troubleshooting 