Code No. P1740: Malfunction of Lockup/Select Switching Solenoid Valve




DIAGNOSTIC FUNCTION




JUDGEMENT CRITERIA



  • The status with the switching solenoid valve ON and with the monitoring value OFF is detected for 0.2 second.
  • The status with the switching solenoid valve OFF and with the monitoring value ON is detected for 0.5 seconds.

PROBABLE CAUSES



  • Malfunction of valve body assembly (Faulty lockup/select switching solenoid valve)
  • Damaged wiring harness and connectors
  • Malfunction of CVT-ECU

DIAGNOSTIC PROCEDURE


STEP 1. M.U.T.-III data list



    Item 36: LU/SEL switching solenoid output
    Item 37: LU/SEL switching solenoid monitor
OK: Check that the output and monitor do not differ greatly.

Q. Is the check result normal?

Intermittent malfunction
Go to Step 2.

STEP 2. Check for open circuit and short to earth in LUOS line between the CVT-ECU connector and the CVT assembly connector.


Q. Is the check result normal?

Go to Step 3.
Repair the wiring harness.

STEP 3. Lockup/select switching solenoid valve single unit check


Refer to .

Q. Is the check result normal?

Go to Step 4.
Replace the valve body assembly.

STEP 4. Symptom recheck after erasing diagnosis code


Q. Is the check result normal?

Intermittent malfunction
Replace CVT-ECU.