Inspection Procedure 14: Multimode keyless entry function does not work at all.



caution Before replacing the ECU, ensure that the power supply circuit, the earth circuit and the communication circuit are normal.


OPERATION




PROBABLE CAUSES



  • Malfunction of the keyless operation key
  • Function setting error or no setting with a customisation
  • Malfunction of ETACS-ECU

DIAGNOSIS PROCEDURE


STEP 1. Check the keyless entry function operation.



Q. Is the check result normal?





STEP 2. Check the operation of the electric-folding door mirror.



Q. Is the check result normal?





STEP 3. Check the customisation





  • D/M: O and C.

Q. Is it set to other than "disabled"?





STEP 4. M.U.T.-III diagnosis code



Q. Is the diagnosis code set?





STEP 5. Check of the troubles



Q. Is the check result normal?