Inspection Procedure 1: The hazard warning lamps do not illuminate.



caution
  • Before replacing the ECU, ensure that the power supply circuit, the earth circuit and the communication circuit are normal.
  • When the ETACS-ECU of vehicles without KOS is replaced, the encrypted code of the ignition key needs to be registered to the ETACS-ECU. (If the encrypted code is not registered, the engine cannot be started. Register the encrypted code as described in Immobilizer System - How to Register Key ID .)


COMMENTS ON TROUBLE SYMPTOM




PROBABLE CAUSES



  • Malfunction of centre panel unit
  • Malfunction of the ETACS-ECU
  • Damaged harness wires and connectors

DIAGNOSIS PROCEDURE


STEP 1. Check that the turn-signal lamps operate.



Q. Is the check result normal?





STEP 2. M.U.T.-III data list




  • Turn ON the hazard lamp switch.
Item No.
Item name
Normal condition
Item 265
Hazard switch
ON
OK: Normal condition is displayed.

Q. Is the check result normal?





STEP 3. Retest the system



Q. Is the check result normal?