1.Disconnect the vacuum hoses from the swirl control valve (SCV) solenoid.
| note |
When disconnecting the vacuum hose, always make sure that it can be reconnected at its
original position.
|
|
|
|
2.Disconnect the harness connector.
|

|
3.Connect a hand vacuum pump to nipple (B) of the swirl control valve (SCV) solenoid. 4.As described in the chart below, check airtightness by applying a vacuum with voltage
applied directly from the battery to the swirl control valve (SCV) solenoid, and without applying
voltage.
|
|
BATTERY POSITIVE VOLTAGE
|
NIPPLE (A) CONDITION
|
NORMAL CONDITION
|
Applied
|
Open
|
Vacuum leaks
|
Closed
|
Vacuum maintained
|
Not applied
|
Closed
|
Vacuum leaks
|
|
|

|
5.Measure the resistance between the terminals of the swirl control valve (SCV) solenoid. Standard value: 29 - 35 Ω (at 20°C) 6.Replace the solenoid if airtightness or resistance is out of specification.
|