VARIABLE GEOMETRY ACTUATOR CHECK <4M4>



1.Remove the vacuum hose from the VG actuator. Connect the hand vacuum pump to the nipple.
caution In order to avoid damage to the diaphragm, do not apply a vacuum of 59 kPa or higher.
2.Apply the vacuum pressure of 55 kpa (to make the VG actuator rod fully small). At that time, check if the VG actuator link is in contact with the stopper bolt.
3.Leak the vacuum pressure gradually as much as possible to check the vacuum pressure when the VG actuator rod moves approximately 1 mm in the extension direction.
Standard value: Approximately 46.3 - 50.0 kPa
4.If the vacuum pressure significantly deviates from the standard value, check the actuator or the variable nozzle. Replace the turbocharger assembly if necessary.