1.Disconnect the A/T control solenoid valve assembly connector. 2.Using the special tool (MB991709), measure the solenoid resistance.
STANDARD VALUE:
Item
|
Measurement terminal No.
|
Normal condition (check condition)
|
Shift solenoid No. 1
|
1 - body earth
|
11 - 15 Ω (at 20°C)
|
Shift solenoid No. 2
|
9 - body earth
|
Shift solenoid SR
|
2 - body earth
|
Linear solenoid No. 1
|
5 -12
|
5.0 - 5.6 Ω (at 20°C)
|
Linear solenoid No. 2
|
6 -13
|
Line pressure control solenoid
|
3 -10
|
Lock-up solenoid
|
4 -11
|
3.If the resistance is not within the standard value, replace the valve body.
|