Code No.P0708: Inhibitor switch system (Short circuit)




INHIBITOR SWITCH SYSTEM CIRCUIT




OPERATION




DIAGNOSIS CODE SET CONDITIONS




PROBABLE CAUSES
  • Malfunction of the inhibitor switch
  • Damaged harness wires and connectors
  • Malfunction of the A/T-ECU

DIAGNOSIS PROCEDURE


STEP 1. Connector check: C-05 Inhibitor switch connector


Check for the contact with terminals.

Q. Is the check result normal?

Go to Step 2.
Repair the defective connector.

STEP 2. Check the inhibitor switch.


Refer to .

Q. Is the check result normal?

Go to Step 3.
Replace the inhibitor switch.

STEP 3. Connector check: D-225 intermediate connector, D-139 A/T-ECU connector


Check for the contact with terminals.

Q. Is the check result normal?

Go to Step 4.
Repair the defective connector.

STEP 4. Check the harness between inhibitor switch connector C-05 terminal No.8, 4, 5, 7 and A/T-ECU connector D-139 terminal No.54, 55, 46, 47.


Check the output line for short circuit.

Q. Is the check result normal?

Go to Step 5.
Repair the wiring harness.

STEP 5. Check whether the diagnosis code is reset.


Check again if the diagnosis code is set.

Q. Is diagnosis code No.P0708 set?

Replace the A/T-ECU.
Intermittent malfunction (Refer to GROUP 00 - How to Cope with Intermittent Malfunction ).