HBB MOTOR RELAY CHECK



caution Apply battery voltage according to the table below. Never confuse the positive and negative battery terminals, or the diode inside the relay will be damaged.


Motor relay 1, 2
Battery connection
Tester connection
Specified condition
-
4 - 5
Open circuit

  • Connect battery terminal (+) to terminal No.3
  • Connect battery terminal (-) to terminal No.1

4 - 5
Continuity (Less than 2 ohms)