INSPECTION PROCEDURE A-1: Central Door Locking System does not Work. <Not Using SWS Monitor>



caution Whenever the ECU is replaced, ensure that the input and output signal circuits are normal.

















COMMENT ON TROUBLE SYMPTOM




POSSIBLE CAUSES



  • Malfunction of the driver’s door lock actuator
  • Malfunction of the ETACS-ECU
  • Damaged harness wires and connectors

DIAGNOSIS PROCEDURE


STEP 1. Check the power supply circuit.



Q. Is the check result normal?





STEP 2. Pulse check



System switch
Check conditions
Driver’s door lock actuator switch
When the driver’s key cylinder or inside lock knob is unlocked or locked
OK: The M.U.T.-III sounds or the voltmeter needle fluctuates.

Q. Is the check result normal?





STEP 3. Connector check: D-419 ETACS-ECU connector


Q. Is the check result normal?





STEP 4. Check the wiring harness between D-419 ETACS-ECU connector terminal No.2 and fusible link (2).


note Prior to the wiring harness inspection, check intermediate connector D-240 and junction block connector D-404, and repair if necessary.

  • Check the power supply line for open or short circuit.

Q. Is the check result normal?





STEP 5. Retest the system.



Q. Is the check result normal?