1.Before inspection, set the vehicle to the pre-inspection condition.
|

|
2.Turn the ignition switch to the "LOCK" (OFF) position and then connect the M.U.T.-III
to the diagnosis connector.
|

|
3.Set the timing light to the power supply line (terminal No. 3) of the ignition coil No.
1.
| note |
The power supply line is looped and also longer than the other ones.
|
4.Start the engine and let it run at idle. 5.Check that ignition timing is at the standard value. Standard value: approximately 10°
BTDC
| note |
- The ignition timing may fluctuate within ±7°. This is normal.
- In higher altitude, the ignition timing is more advanced than the standard value
by approximately 5°.
- Wait till approximately 1 minute passes after the engine started, and check the
ignition timing when the engine stabilized.
|
6.Run the engine at 2,000 - 3,000 r/min for 2 minutes. 7.Set the CO, HC tester. 8.Check the CO contents and the HC contents at idle. Standard value
CO contents: 0.3 %
or less HC contents: 200 ppm or less
9.If there is a deviation from the standard value, inspect the MPI system (Refer to
GROUP 13A -
Troubleshooting -
Inspection Chart for Trouble Symptoms ). 10.Turn the ignition switch to the "LOCK" (OFF) position and then remove the M.U.T.-III.
|