Inspection Procedure 14: Battery rundown <Vehicles without battery current sensor>










COMMENT ON TROUBLE SYMPTOM



  • Failure is possibly caused by failed alternator, failed generation control circuit or other faults.

PROBABLE CAUSES



  • Failed battery
  • Open/short circuit or harness damage in alternator L terminal circuit
  • Failed alternator

DIAGNOSIS PROCEDURE


STEP 1. Check battery.



  • Check battery (Refer to GROUP 54A - Battery - On-vehicle Service - Battery Test ).

Q. Is the check result normal?

Go to Step 2.
Replace the battery.

STEP 2. Connector check: B-20 intermediate connector


Q. Is the check result normal?

Go to Step 3 .
Repair or replace the connector.

STEP 3. Perform voltage measurement at B-20 intermediate connector.



  • Disconnect connector, and measure at male connector side.
  • Ignition switch: ON
  • Voltage between terminal No. 3 and earth.
OK: System voltage

Q. Is the check result normal?

Go to Step 6 .
Go to Step 4 .

STEP 4. Connector check: D-02 combination meter connector


Q. Is the check result normal?

Go to Step 5 .
Repair or replace the connector.

STEP 5. Check harness between B-20 (terminal No. 3) intermediate connector and D-02 (terminal No. 47) combination meter connector.


note Before checking harness, check intermediate connector D-230, and repair if necessary.

  • Check power supply line for open/short circuit.

Q. Is the check result normal?

Check the combination meter (Refer to GROUP 54A - Combination Meter - Trouble Symptom Chart ).
Repair the damaged harness wire.

STEP 6. Connector check: B-116 alternator connector


Q. Is the check result normal?

Go to Step 7 .
Repair or replace the connector.

STEP 7. Perform voltage measurement at B-116 Alternator connector.



  • Disconnect connector, and measure at harness side.
  • Ignition switch: ON
  • Voltage between terminal No. 3 and earth.
OK: System voltage

Q. Is the check result normal?

Go to Step 8 .

    Check and repair harness between B-20 (terminal No. 3) intermediate connector and B-116 (terminal No. 3) alternator connector.

    • Check power supply line for open/short circuit.

STEP 8. Connector check: D-02 combination meter connector


Q. Is the check result normal?

Go to Step 9 .
Repair or replace the connector.

STEP 9. Check harness between B-116 (terminal No. 3) alternator connector and D-02 (terminal No. 47) combination meter connector.


note Before checking harness, check intermediate connector D-230, and repair if necessary.

  • Check power supply line for damage.

Q. Is the check result normal?

Check the alternator.
Repair the damaged harness wire.