1.Immerse the thermostat in water, and heat the water while stirring. Check the thermostat
valve opening temperature.
Standard value:
<6G75, 4M4> 82 ± 2°C <6G72> 88 ± 2°C
|

|
2.Check that the amount of valve lift is at the standard value when the water is at the
full-opening temperature.
| note |
Measure the valve height when the thermostat is fully closed, and use this measurement
to compare the valve height when the thermostat is fully open.
|
Standard value:
Full-opening temperature:
<6G75, 4M4> 95 °C <6G72> 100 °C
Amount of valve lift: 10 mm or more
|