1.Remove the exhaust gas recirculation valve and inspect for sticking, carbon deposits,
etc. If found, clean with a suitable solvent so that the valve seats correctly.
|
|
|
2.Connect a hand vacuum pump to the exhaust gas recirculation valve.
|
|
|
3.Apply 67 kPa of vacuum, and check that the vacuum is maintained.
|

|
4.Apply a vacuum and check the passage of air by blowing through one side of the exhaust
gas recirculation passage.
|
|
Vacuum
|
Passage of air
|
5.6 kPa or less
|
Air is not blown out
|
29 kPa or more
|
Air is blown out
|
|
5.Replace the gasket, and tighten to the specified torque. Tightening torque: 23 ± 6 N·m
|