INHIBITOR SWITCH AND CONTROL CABLE ADJUSTMENT


1.Move the selector lever to the N position.
2.Loosen the adjusting nut, and set the manual control lever upper and lower to the free condition.
3.Move the manual control lever lower to the neutral position.

4.Align the hole at the end of the manual control lever lower and the hole in the inhibitor switch flange (section A - A in the illustration at left).
note The inhibitor switch can be aligned by inserting a 5-mm bar in the holes of the manual control lever end and the inhibitor switch flange.

5.Gently push the transmission control cable in the direction as shown in the illustration at left, and tighten the adjusting nut the specified torque.
Tightening torque: 23 ± 4 N·m
6.Check that the selector lever is at the N position.
7.Check that the transmission shifts to the correct range corresponding to the position of the selector lever, and that it functions correctly in that range.