OUTPUT SHAFT SPEED SENSOR CHECK



1.Disconnect the output shaft speed sensor connector.
2.Measure the resistance between terminals 1 and 2 of the output shaft speed sensor connector.
Standard value: 560 - 680 Ω (at 20°C)
3.If the resistance is not within the standard value, replace the output shaft speed sensor.