INSPECTION




1. INSPECT SOLENOID ASSY (S1, S2, SR)



1.
caution
  • Do not apply impact to the solenoid assy.
  • Do not damage the terminals
With a tester, measure the resistance between the solenoid assy terminal and the solenoid assy body.
Standard value: 11 - 15Ω (at 20 degrees C)
note If the resistance value is not within the specified, replace the solenoid assy with a new one.

2.
caution
  • Do not apply impact to the solenoid assy.
  • Do not damage the terminals
Check that the solenoid assy operates when connecting the positive battery terminal to the solenoid assy terminal, and the negative battery terminal to the solenoid assy body.
note If the solenoid assy does not operate, replace it with a new one.

3.
caution
  • Do not apply impact to the solenoid assy.
  • Do not damage the terminals
Check that the valve in the solenoid assy operates when the solenoid assy terminal is connected to the positive battery terminal and the solenoid assy body is connected to the negative battery terminal.
note If the solenoid assy does not operate, replace it with a new one.