INSPECTION PROCEDURE A-2: A Door can not be Locked or Unlocked by the Central Door Locking System. <RH drive vehicles>
| caution | Whenever the ECU is replaced,
ensure that the input and output signal circuits are normal. |














COMMENT ON TROUBLE SYMPTOM
POSSIBLE CAUSES
- Malfunction of the door lock actuator
- Damaged harness wires and connectors
DIAGNOSIS PROCEDURE
STEP 1. Confirm which door lock actuator is defective.
Q.
Which door fails to lock correctly?





STEP 2. Connector check: F-15 door lock actuator (front: RH) connector
Q.
Is the check result normal?


STEP 3. Check the door lock actuator (front: RH)

Q.
Is the check result normal?


STEP 4. Connector check: D-419 ETACS-ECU connector
Q.
Is the check result normal?


STEP 5. Check the wiring harness from D-419 ETACS-ECU connector terminal Nos. 12, 13 to F-15 door lock actuator (front: RH) connector terminal Nos. 4, 6.
| note | Prior to the wiring harness inspection, check intermediate connector D-114 and junction
block connector D-405, and repair if necessary. |
- Check the input and output lines for open circuit.
Q.
Is the check result normal?



STEP 6. Connector check: F-05 door lock actuator (front: LH) connector
Q.
Is the check result normal?


STEP 7. Check the door lock actuator (front: LH).

Q.
Is the check result normal?


STEP 8. Connector check: D-419 ETACS-ECU connector
Q.
Is the check result normal?


STEP 9. Check the wiring harness from D-419 ETACS-ECU connector terminal Nos. 12, 13 to F-05 door lock actuator (front: LH) connector terminal Nos. 6, 4
| note | Prior to the wiring harness inspection, check intermediate connector D-133 and junction
block connector D-405, and repair if necessary. |
- Check the input and output lines for open circuit.
Q.
Is the check result normal?



STEP 10. Connector check: F-24 door lock actuator (rear: RH) connector
Q.
Is the check result normal?


STEP 11. Check the door lock actuator (rear: RH).

Q.
Is the check result normal?


STEP 12. Connector check: D-419 ETACS-ECU connector
Q.
Is the check result normal?


STEP 13. Check the wiring harness from D-419 ETACS-ECU connector terminal Nos. 12, 13 to F-24 door lock actuator (rear: RH) connector terminal Nos. 6, 4.
| note | Prior to the wiring harness inspection, check intermediate connector E-43 and junction
block connector D-422, and repair if necessary. |
- Check the input and output lines for open circuit.
Q.
Is the check result normal?



STEP 14. Connector check: F-16 door lock actuator (rear: LH) connector
Q.
Is the check result normal?


STEP 15. Check the door lock actuator (rear: LH).

Q.
Is the check result normal?


STEP 16. Connector check: D-419 ETACS-ECU connector
Q.
Is the check result normal?


STEP 17. Check the wiring harness from D-419 ETACS-ECU connector terminal Nos. 12, 13 to F-16 door lock actuator (rear: LH) connector terminal Nos. 4, 6.
| note | Prior to the wiring harness inspection, check intermediate connectors D-236, E-42 and
junction block connector D-405, and repair if necessary. |
- Check the input and output lines for open circuit.
Q.
Is the check result normal?



STEP 18. Connector check: G-13 back door lock actuator connector
Q.
Is the check result normal?


STEP 19. Check the back door lock actuator.

Q.
Is the check result normal?


STEP 20. Connector check: D-419 ETACS-ECU connector
Q.
Is the check result normal?


STEP 21. Check the wiring harness from D-419 ETACS-ECU connector terminal Nos. 12, 13 to G-13 back door lock actuator connector terminal Nos. 6, 4.
| note | Prior to the wiring harness inspection, check intermediate connectors E-105 and junction
block connector D-422, and repair if necessary. |
- Check the input and output lines for open circuit.
Q.
Is the check result normal?