INSPECTION PROCEDURE A-3: The Central Door Locking System does not function by using The Door Lock Switch (incorporated with the power windows main switch). <Using SWS Monitor>



caution Whenever the ECU is replaced, ensure that the input and output signal circuits are normal.





COMMENT ON TROUBLE SYMPTOM




POSSIBLE CAUSES



  • Malfunction of the door lock switch (incorporated with the power windows main switch)
  • Malfunction of the ETACS-ECU
  • Damaged harness wires and connectors

DIAGNOSIS PROCEDURE


Step 1. ETACS switch data by using the SWS monitor




  • Door lock switch: Neutral to lock
Item No.
Item name
Normal condition
Item 26
Centre door lock switch
ON (only when operated to lock)
Item 27
Centre door unlock switch
OFF

  • Door lock switch: Neutral to unlock
Item No.
Item name
Normal condition
Item 26
Centre door lock switch
OFF
Item 27
Centre door unlock switch
ON (only when operated to unlock)
OK: Normal condition are displayed for all the items.

Q. Are the check result normal?





Step 2. Retest the system.



Q. Is the check result normal?