INSPECTION PROCEDURE A-3: The Central Door Locking System does not function by using The Door Lock Switch (incorporated with the power windows main switch). <Not Using SWS Monitor>



caution Whenever the ECU is replaced, ensure that the input and output signal circuits are normal.





COMMENT ON TROUBLE SYMPTOM




POSSIBLE CAUSES



  • Malfunction of the door lock switch (incorporated with the power windows main switch)
  • Malfunction of the ETACS-ECU
  • Damaged harness wires and connectors

DIAGNOSIS PROCEDURE


STEP 1. Check the operation of the central door locking system.



Q. Is the check result normal?





STEP 2. Pulse check



System switch
Check condition
Door lock switch (incorporated with the power windows main switch)
When the door lock switch is unlocked or locked
OK: The M.U.T.-III sound or the voltmeter needle fluctuate.

Q. Is the check result normal?





STEP 3. Retest the system.



Q. Is the check result normal?