INSPECTION PROCEDURE B-3: The Timer Lock Function does not work after The Doors have been Unlocked by The Keyless Entry System.



caution Whenever the ECU is replaced, ensure that the input and output signal circuits are normal.


COMMENT ON TROUBLE SYMPTOM





POSSIBLE CAUSES



  • Malfunction of the keyless entry transmitter
  • Malfunction of the ETACS-ECU
  • Damaged harness wires and connectors

DIAGNOSIS PROCEDURE


STEP 1. Check the operation of the keyless entry system.



Q. Is the check result normal?





STEP 2. Customisation function by using the SWS monitor.




  • 30sec.
  • 60sec.
  • 120sec.
  • 180sec.

Q. Is the check result normal?