Inspection Procedure 1: The Approach Lamps does not Illuminate or Extinguish Normally.























COMMENTS ON TROUBLE SYMPTOM


The ETACS-ECU operates the approach lamps in accordance with the input signals below.

  • Ignition switch (IG1)
  • Door switches
  • Back door switch
  • Driver’s door lock actuator switch (unlock switch)
If this function does not work normally, these input signal circuit(s) or the ETACS-ECU may be defective.

PROBABLE CAUSES



  • Malfunction of the door switches
  • Malfunction of the driver’s door lock actuator switch (unlock switch)
  • Malfunction of the ETACS-ECU
  • Damaged harness wires and connectors

DIAGNOSIS PROCEDURE


STEP 1. SWS monitor data list


<Selected item> ETACS ECU
  • Driver’s door is open
Item No.
Item name
Normal condition
Item 32
DR DOOR SW
ON
OK: Normal condition is displayed.

Q. Is the check result normal?

Go to Step 2.
Refer to ETACS - Input Signal Chart .

STEP 2. ETACS switch data by using the SWS monitor


Check the ETACS-ECU signal related to the room lamp illumination.

  • Ignition switch: OFF (key inserted)
Item No.
Item name
Normal condition
Item 03
Key reminder switch
OFF

  • Passenger’s door: Close → Open
Item No.
Item name
Normal condition
Item 05
Passenger’s door switch
from OFF to ON

  • Back door: Close → Open
Item No.
Item name
Normal condition
Item 07
Rear and back gate door switch
from OFF to ON

  • Rear door (RH): Close → Open
Item No.
Item name
Normal condition
Item 41
Rear door (right side) switch
from OFF to ON

  • Rear door (LH): Close → Open
Item No.
Item name
Normal condition
Item 42
Rear door (left side) switch
from OFF to ON

  • Driver’s door: Unlock → Lock
Item No.
Item name
Normal condition
Item 21
Dr door lock actuator lock SW
OFF
Item 22
Dr door lock actuator unlock SW
from ON to OFF
OK: Normal conditions displayed for all the items.

Q. Is the check result normal?

YES (Normal conditions are displayed for all the items) : Go to Step 3.
NO (Normal condition is not displayed for item No.03) : Refer to ETACS - Input Signal Chart .
NO (Normal condition is not displayed for item No.05, 07, 41 or 42) : Refer to ETACS - Input Signal Chart .
NO (Normal condition is not displayed for item No.21 and 22) : Refer to ETACS - Input Signal Chart .

STEP 3. Retest the system.


Check that the approach lamps illuminate normally.

Q. Is the check result normal?

The trouble can be an intermittent malfunction (Refer to GROUP 00 - How to Cope with Intermittent Malfunction ).
Go to Step 4.

STEP 4. Fuse check: Fuse No.8 and No.24.


Q. Is the check result normal?

Go to Step 5.
Replace the fuse.

STEP 5. Check the bulb of the approach lamps.


Check the bulb of the defective lamp.

Q. Is the check result normal?

Go to Step 6.
Replace the bulb(s) of the defective lamp.

STEP 6. Connector check: F-09-1 approach lamp (RH) or F-04-1 approach lamp (LH) connector.


Q. Is the check result normal?

Go to Step 7.
Repair the defective connector.

STEP 7. Check the wiring harness from fusible link No.1 to F-09-1 approach lamp (RH) connector terminal No.2 or F-04-1 approach lamp (LH) connector terminal No.2.


note Prior to the wiring harness inspection, check intermediate connector D-114 <approach lamp (RH)>, D-133 <approach lamp (LH)>, D-238, door mirror assembly connector F-04 (LH) and F-09 (RH), and repair if necessary.

  • Check the power supply line for open circuit.

Q. Is the check result normal?

Go to Step 8.
Repair the wiring harness.

STEP 8. Connector check: D-420 ETACS-ECU connector


Q. Is the check result normal?

Go to Step 9.
Repair the defective connector.

STEP 9. Check the wiring harness from D-420 ETACS-ECU connector terminal No.52 to F-09-1 approach lamp (RH) connector terminal No.1 or F-04-1 approach lamp (LH) connector terminal No.1.


note Prior to the wiring harness inspection, check intermediate connector D-114 <approach lamp (RH)>, D-133 <approach lamp (LH)>, joint connector D-34, door mirror assembly connector F-04 (LH) and F-09 (RH), and repair if necessary.

  • Check the earth wirers for open circuit.

Q. Is the check result normal?

Go to Step 10.
Repair the wiring harness.

STEP 10. Retest the system.


Check that the approach lamps illuminate normally.

Q. Is the check result normal?

The trouble can be an intermittent malfunction (Refer to GROUP 00 - How to Cope with Intermittent Malfunction ).
Replace the ETACS-ECU.