Code No.U1006 Security alarm siren LIN timeout



caution Before replacing the ECU, ensure that the communication circuit is normal.










DIAGNOSTIC FUNCTION



note Diagnosis code No.U1006 will be stored in the CAN converter-ECU when the ignition switch is turned to the ON position with the power supply fuse (IOD fuse) removed. Therefore, diagnosis code No.U1006 may be stored as a past trouble even though the vehicle is normal. However, it is not a malfunction.

PROBABLE CAUSES



  • Faulty security alarm siren
  • Faulty CAN converter-ECU
  • Faulty LIN cutoff control unit
  • Malfunction of the wiring harness

DIAGNOSIS PROCEDURE


STEP 1. Check whether the diagnosis code is reset.


Check again if the diagnosis code No. U1006 is set to the CAN converter-ECU.
(1)Erase the diagnosis code.
(2)Turn the ignition switch from the LOCK (OFF) position to the ON position.
(3)Check if diagnosis code is set.

Q. Is the diagnosis code No.U1006 set?

Go to Step 2.
Diagnosis complete.

STEP 2. Connector check: D-253 CAN converter-ECU connector, D-47 LIN cutoff control unit connector, A-53 security alarm siren connector


Q. Is the check result normal?

Go to Step 3.
Repair the defective connector.

STEP 3. Resistance measurement at the A-52 security alarm siren connector


(1)Disconnect the connector, and measure at the wiring harness side.
(2)Measure the resistance between the A-52 security alarm siren connector terminal No. 1 and the body earth.
OK: Continuity exists (2 Ω or less)

Q. Is the check result normal?

Go to Step 5.
Go to Step 4.

STEP 4. Wiring harness check from A-52 security alarm siren connector terminal No. 1 to body earth


Check the earth wires for open circuit.
note Prior to the wiring harness inspection, check intermediate connector A-53, and repair if necessary.

Q. Is the check result normal?

The trouble can be an intermittent malfunction (Refer to GROUP 00 - How to use Troubleshooting/inspection Service Points - How to Cope with Intermittent Malfunction ).
Repair the wiring harness.

STEP 5. Voltage measurement at the A-52 security alarm siren connector.


(1)Disconnect the connector, and measure at the wiring harness side.
(2)Measure the voltage between the A-52 security alarm siren connector terminal No. 2 and the body earth.
OK: System voltage

Q. Is the check result normal?

Go to Step 7.
Go to Step 6.

STEP 6. Wiring harness check between the A-52 security alarm siren connector terminal No. 2 and fusible link (1)


Check the power supply line for open circuit and short circuit.
note Prior to the wiring harness inspection, check intermediate connector A-53, and repair if necessary.

Q. Is the check result normal?

The trouble can be an intermittent malfunction (Refer to GROUP 00 - How to use Troubleshooting/inspection Service Points - How to Cope with Intermittent Malfunction ).
Repair the wiring harness.

STEP 7. LIN cutoff control unit check


Check the LIN cutoff control unit. Refer to GROUP 54A - Security Alarm System .

Q. Is the check result normal?

Go to Step 8.
Replace the LIN cutoff control unit.

STEP 8. Voltage measurement at the D-252 CAN converter-ECU connector.


(1)Disconnect the connector, and measure at the wiring harness side.
(2)Measure the voltage between the D-252 CAN converter-ECU connector terminal No. 5 and the body earth.
OK: System voltage

Q. Is the check result normal?

Go to Step 11.
Go to Step 9.

STEP 9. Wiring harness check between the fusible link (1) and the D-41 LIN cutoff control unit connector terminal No. 1


Check the power supply line for open circuit and short circuit.

Q. Is the check result normal?

Go to Step 10.
Repair the wiring harness.

STEP 10. Wiring harness check between the D-41 LIN cutoff control unit connector terminal No. 8 and the D-252 CAN converter-ECU connector terminal No. 5


Check the power supply line for open circuit and short circuit.

Q. Is the check result normal?

Go to Step 13.
Repair the wiring harness.

STEP 11. Check the wiring harness wires between D-252 CAN converter-ECU connector terminal No. 12 and D-41 LIN cutoff control unit connector terminal No. 7.


Check the communication lines for open circuit.

Q. Is the check result normal?

Go to Step 12.
Repair the wiring harness.

STEP 12. Check the wiring harness wires between D-41 LIN cutoff control unit connector terminal No. 5 and A-52 security alarm siren connector terminal No. 3.


note Prior to the wiring harness inspection, check intermediate connectors A-53 and D-241, and repair if necessary.
Check the communication lines for open circuit.

Q. Is the check result normal?

Go to Step 13.
Repair the wiring harness.

STEP 13. Replace the security alarm siren temporarily, and check whether the diagnosis code is set.


Check again if the diagnosis code is set to the CAN converter-ECU.
(1)Erase the diagnosis code.
(2)Turn the ignition switch from the LOCK (OFF) position to the ON position.
(3)Check if diagnosis code is set.

Q. Is the diagnosis code set?

Replace the CAN converter-ECU.
Replace the security alarm siren.