Inspection Procedure 6: Interior Lamp Automatic Shutoff Function does not Work Normally. <Vehicles with Keyless Entry System (Using SWS Monitor)>



caution Whenever the ECU is replaced, ensure that the input and output signal circuits are normal.


COMMENTS ON TROUBLE SYMPTOM




  • Ignition switch (ACC)
  • Ignition switch (IG1)
  • Driver’s door switch
  • Back door switch
  • All of the door switches
  • Interior lamp loaded signal


PROBABLE CAUSES



  • Malfunction of the door switches
  • Malfunction of the back door switch
  • Malfunction of the interior lamp
  • Malfunction of the ETACS-ECU
  • Damaged harness wires and connectors

DIAGNOSIS PROCEDURE


STEP 1. Customize function by using the SWS monitor




  • 3min.
  • 30min.
  • 60min.

Q. Is the check result normal?





STEP 2. ECU check by using the SWS monitor




  • Ignition switch: OFF
ECU TO BE CHECKED
  • ETACS
OK: "OK" is displayed on the "ETACS ECU" menu.

Q. Is the check result normal?





STEP 3. SWS monitor data list.



<Selected item> ETACS ECU
  • Ignition switch: OFF
  • Driver’s door: open
Item No.
Item name
Normal condition
Item 30
IG SW(IG1)
OFF
Item 31
IG SW(ACC)
OFF
Item 32
DR DOOR SW
ON
OK: Normal condition is displayed.

Q. Is the check result normal?









STEP 4. ETACS switch data by using the SWS monitor




  • Passenger’s door: Close → Open
Item No.
Item name
Normal condition
Item 05
Passenger’s door switch
from OFF to ON

  • Back door: Close → Open
Item No.
Item name
Normal condition
Item 07
Rear and back gate door switch
from OFF to ON

  • Rear door (RH): Close → Open
Item No.
Item name
Normal condition
Item 41
Rear door (right side) switch
from OFF to ON

  • Rear door (LH): Close → Open
Item No.
Item name
Normal condition
Item 42
Rear door (left side) switch
from OFF to ON
OK: Normal conditions are displayed for all the items.

Q. Is the check result normal?





STEP 5. Pulse check



System switch
Check condition
Interior lamp loaded signal
When a load is applied through fuse No.18
OK: The M.U.T.-III sounds or the voltmeter needle fluctuates.

Q. Is the check result normal?





STEP 6. Retest the system.



Q. Is the check result normal?