COSTOMISATION FUNCTION



Item No.
Items shown on M.U.T.-III screen
Item
Adjustment items shown on M.U.T.-III screen
Adjusting contents
1
Sensitivity for auto-lamp
Lighting control sensor sensitivity (illumination intensity)
Sensitive
High ambient brightness
Normal
Standard ambient brightness (initial condition)
Insensitive
Low ambient brightness
More insensitive
Low-low ambient brightness
2
Headlamp auto-cut
Headlamp automatic-shutdown function
Spec.B(EU/EXP)
With function: The automatic tail lamp turn-off function with the ignition switch OFF (LOCK) is not available. (initial condition)
Without function
Without function
4
Wiper speed-sensitive operation
Vehicle speed-dependent wiper function
With function
With function (initial condition)
Without function
Without function
11
Security alarm function
alarm <Vehicles with security alarm sensor>
Sound/Hazard
With function (initial condition)
Without function
Without function
15
Turn-signal buzzer
Turn-signal lamp buzzer function
With function
With function
Without function
Without function (initial condition)
16
Room lamp delay timer
Dimmer interior lamp control duration
30 sec.
30 seconds
15 sec.
15 seconds (initial condition)
7.5 sec.
7.5 seconds
Without function
0 second (no delay action)
24
Timer relock after unlocking
Timer lock time after executing the keyless entry unlock
30 sec.
30 seconds (initial condition)
60 sec.
1 minute
120 sec.
2 minutes
180 sec.
3 minutes
26
Door ajar buzzer
Door-ajar warning function
With function
With function (initial condition)
Without function
Without function
Sequential ope.
Continuous operation
28
Rear wiper intermittent time
Rear wiper intermittent duration
8 sec.
8 seconds: Without continuous operation (initial condition)
4s(Sequential*)
4 seconds: With continuous operation
8s(Sequential*)
8 seconds: With continuous operation
16s(Sequential*)
16 seconds: With continuous operation
Sequential* ope.
Continuous operation (without the intermittence)
4 sec.
4 seconds: Without continuous operation
16 sec.
16 seconds: Without continuous operation
30
Room lamp auto-cut
Operation duration of interior lamp automatic-shutoff function
3min.
3 minutes
30min.
30 minutes (initial condition)
60min.
60 minutes
Without function
Without function
31
P/W lock-mode operation
Power window lock operation on the driver’s seat
All SW operable
Driver can operate power windows on all doors even when the power window lock is ON (initial condition).
Only main SW
Operating seats other than the driver’s seat is prohibited when lock is ON.
33
Sensitivity for security sensor
Sensitivity level setting of security alarm sensor <Vehicles with security alarm sensor>
Level 1
100% sensitivity of security alarm sensor (initial condition)
Level 2
90% sensitivity of security alarm sensor
Level 3
80% sensitivity of security alarm sensor
Level 4
70% sensitivity of security alarm sensor
37
Wiper synchronized washer
Wiper linked with washer function
With function
With function (initial condition)
Without function
Without function
39
Turn-signal operation
Turn signal lamp operation condition adjustment function
When IG ON
Turn signal lamp can be operated when the ignition switch is turned ON (initial condition).
When IG ACC
Turn signal lamp can be operated when the ignition switch is in ACC or ON position.
40
Hazard answer-back operation
Keyless entry hazard answer-back flashing pattern adjustment function
LOCK: 1/UNLOCK: 2
LOCK: Flash once, UNLOCK: Flash twice (initial condition)
LOCK: 1/UNLOCK: 0
LOCK: Flash once, UNLOCK: No flash
LOCK: 0/UNLOCK: 2
LOCK: No flash, UNLOCK: Flash twice
LOCK: 2/UNLOCK: 1
LOCK: Flash twice, UNLOCK: Flash once
LOCK: 2/UNLOCK: 0
LOCK: Flash twice, UNLOCK: No flash
LOCK: 0/UNLOCK: 1
LOCK: No flash, UNLOCK: Flash once
Without function
No flashing
60
Reception of comfort flasher
Comfort flasher function
400 msec
With function: Switch acceptance time is 0.4 second or less. (initial condition)
800 msec
With function: Switch acceptance time is 0.8 second or less.
Without function
Without function
note
  • *: The wiper operates consecutively when the rear wiper switch is operated twice in less than one second.
  • Adjustment items other than the above will also be shown on M.U.T.-III screen. However, they cannot be reconfigured.