Inspection Procedure 9: The A/C indicator flashes
CIRCUIT OPERATION
TROUBLESHOOTING HINTS
- Improper amount of refrigerant
- Malfunction of the A/C-ECU
DIAGNOSIS PROCEDURE |
STEP 1. M.U.T.-III diagnosis code |
| Check that the diagnosis code related to the A/C is not set. |
Q.
Is the check result normal?
|
Go to Step 2. |
|
Carry out the diagnosis code procedures. Refer to . |
|
STEP 2. Remove the refrigerant, and fill it to the specified amount. |
Remove the refrigerant and fill it to the specified amount. Then check if the A/C operates normally. Refer to . |
Q.
Is the check result normal?
|
This diagnosis is complete. |
|
Go to Step 3. |
|
STEP 3. Recheck the trouble symptom |
| Check that the compressor works normally. |
Q.
Is the check result normal?
|
This diagnosis is complete. |
|
Replace the A/C-ECU. |
|

Carry out the diagnosis code procedures. Refer to 