Inspection Procedure 6: Obstacle is not detected even when the selector or shift lever is shifted to "R" (Reverse) position.



caution
  • Whenever the ECU is replaced, ensure that the input signal circuit is normal.
  • When the illuminated licence plate is installed, the sensors may not operate because of noise from the plate. (When the ultrasonic noise is received, the bass toned buzzer sound continuously. When the ultrasonic noise stops, the normal operation will be resumed immediately.)


COMMENTS ON TROUBLE SYMPTOM



note If ultrasonic noise is received with the sensor, the corner sensor/back sensor sounds the low toned buzzer continuously and turns off the system. When the ultrasonic noise is stopped, the sensor returns to normal.

PROBABLE CAUSES



  • Damaged harness wires and connectors
  • Malfunction of the inhibitor switch <CVT> or back-up lamp switch <M/T>
  • Malfunction of corner sensor/back sensor-ECU

DIAGNOSIS PROCEDURE


STEP 1. M.U.T.-III CAN bus diagnostics



Q. Is the check result normal?





STEP 2. M.U.T.-III other system diagnosis code



Q. Is the check result normal?





STEP 3. Check the reversing sensor (corner sensor/back sensor) for interference.


Q. Is there anything that interferes with the communication (things that generate radio waves such as magnets and an air-cleaning device that has a power plug) near the reversing sensor (corner sensor/back sensor)?





STEP 4. Connector check: C-403 ETACS-ECU connector and B-122 inhibitor switch connector <CVT> or B-109 back-up lamp switch connector <M/T>.


Q. Is the check result normal?





STEP 5. Voltage measurement at C-403 ETACS-ECU connector.


(1)Disconnect C-403 ETACS-ECU connector, and measure at the wiring harness side.
(2)Turn the ignition switch to the "ON" position, and move the selector lever <CVT> or the shift lever <M/T> to the "R" position.
(3)Measure the voltage between terminal No. 2 and earth.
OK: System voltage

Q. Is the check result normal?





STEP 6. Check the wiring harness between B-122 inhibitor switch connector terminal No. 9 <CVT> or B-109 back-up lamp switch connector terminal No. 1 <M/T> and C-403 ETACS-ECU connector terminal No. 2.



  • Check the communication line for open circuit or short circuit.
note Before the wiring harness inspection, inspect the intermediate connectors A-17 <Except 1800-Diesel> and B-108 <1800-Diesel>, and repair if necessary.

Q. Is the check result normal?





STEP 7. Voltage measurement at B-122 inhibitor switch connector <CVT> or B-109 back-up lamp switch connector <M/T>.


(1)Disconnect B-122 inhibitor switch connector <CVT> or B-109 back-up lamp switch connector <M/T>, and measure at the wiring harness side.
(2)Turn the ignition switch to "ON" position.
(3)Measure the voltage between B-122 inhibitor switch connector <CVT> terminal No. 3 or back-up lamp switch connector <M/T> terminal No. 2 and earth.
OK: System voltage

Q. Is the check result normal?





STEP 8. M.U.T.-III other system service data




  • Turn the ignition switch to the ON position.
Item No.
Item name
Normal condition
Item 254
IG voltage
System voltage
OK: Normal condition is displayed.

Q. Is the check result normal?





STEP 9. Check the wiring harness between B-122 inhibitor switch connector <CVT> terminal No. 3 or B-109 back-up lamp switch connector <M/T> terminal No. 2 and fusible link 34 <Except 1800-Diesel> or 44 <1800-Diesel>.



  • Check the communication line for open circuit or short circuit.
note Before the wiring harness inspection, inspect the intermediate connectors A-17 <Except 1800-Diesel> and B-108 <1800-Diesel> and C-28, and ETACS-ECU connectors C-408 and C-412, and repair if necessary.

Q. Is the check result normal?





STEP 10. Check the inhibitor switch <CVT> or back-up lamp switch <M/T>.



Q. Is the check result normal?





STEP 11. Retest the system



Q. Is the check result normal?