Inspection Procedure 5: Although READY indicator (green lamp) is lit, CHARGE indicator (orange lamp) is not lit. (Regular charging is impossible.)


COMMENTS ON TROUBLE SYMPTOM
PROBABLE CAUSES
- The charging cable is failed.
- Open circuits of pilot signal circuit and damage; poor contacts of connector
- The on board charger is failed.
DIAGNOSIS PROCEDURE |
STEP 1. Check the trouble symptom |
Q.
Does the trouble symptom persist?
|
Go to Step 2 . |
|
Intermittent malfunction (Refer to GROUP 00 - How to Use Troubleshooting/Inspection
Service Points - How to Cope with Intermittent Malfunctions ). |
|
STEP 2. Check pilot signal terminal itself |
Q.
Is the check result normal?
|
Go to Step 3 . |
|
Replace the charging cable. |
|
STEP 3. Connector check: G-03 regular charging connector and E-03 on board charger/DC-DC converter connector |
Q.
Are the check results normal?
|
Go to Step 4 . |
|
Repair or replace the connector. |
|
STEP 4. Check harness between G-03 (terminal No. 3) regular charging connector and E-03 (terminal No. 9) on board charger/DC-DC converter. |
|
|
Q.
Is the check result normal?
|
Replace the on board charger/DC-DC converter. |
|
Repair the damaged harness wire. |
|

Intermittent malfunction (Refer to GROUP 00 - How to Use Troubleshooting/Inspection
Service Points - How to Cope with Intermittent Malfunctions 