Inspection Procedure 5: Although READY indicator (green lamp) is lit, CHARGE indicator (orange lamp) is not lit. (Regular charging is impossible.)








COMMENTS ON TROUBLE SYMPTOM




PROBABLE CAUSES



  • The charging cable is failed.
  • Open circuits of pilot signal circuit and damage; poor contacts of connector
  • The on board charger is failed.

DIAGNOSIS PROCEDURE


STEP 1. Check the trouble symptom


Q. Does the trouble symptom persist?

Go to Step 2 .
Intermittent malfunction (Refer to GROUP 00 - How to Use Troubleshooting/Inspection Service Points - How to Cope with Intermittent Malfunctions ).

STEP 2. Check pilot signal terminal itself



  • Check Charging Cable (Refer to ).

Q. Is the check result normal?

Go to Step 3 .
Replace the charging cable.

STEP 3. Connector check: G-03 regular charging connector and E-03 on board charger/DC-DC converter connector


Q. Are the check results normal?

Go to Step 4 .
Repair or replace the connector.

STEP 4. Check harness between G-03 (terminal No. 3) regular charging connector and E-03 (terminal No. 9) on board charger/DC-DC converter.


note Before checking harness, check intermediate connector G-12, and repair if necessary.

  • Check signal line for open circuits and damage.

Q. Is the check result normal?

Replace the on board charger/DC-DC converter.
Repair the damaged harness wire.