INSPECTION PROCEDURE D-1: Dead Lock System does not work at All.



caution Whenever the ECU is replaced, ensure that the input and output signal circuits are normal.






COMMENT ON TROUBLE SYMPTOM




PROBABLE CAUSES



  • Malfunction of the dead lock relay
  • Malfunction of the ETACS-ECU
  • Damaged harness wires and connectors

DIAGNOSIS PROCEDURE


STEP 1. Check the operation of the keyless entry system.



Q. Is the check result normal?





STEP 2. Check the power supply circuit.



Q. Is the check result normal?





STEP 3. Connector check: C-302 dead lock relay connector


Q. Is the check result normal?





STEP 4. Check the dead lock relay.



Q. Is the check result normal?





STEP 5. Voltage measurement at C-302 dead lock relay connector.


(1)Disconnect the connector, and measure at the wiring harness side.
(2)Check the voltage between the C-302 dead lock relay connector terminal No.1 and body earth.
OK: Battery positive voltage

Q. Is the check result normal?





STEP 6. Check the wiring harness between C-302 dead lock relay connector terminal No.1 and fusible link (38).


note Prior to the wiring harness inspection, check ETACS-ECU connector C-309, and repair if necessary.

  • Check the power supply line for open or short circuit.

Q. Is the check result normal?





STEP 7. Voltage measurement at C-302 dead lock relay connector.


(1)Disconnect the connector, and measure at the wiring harness side.
(2)Check the voltage between the C-302 dead lock relay connector terminal No.3 and body earth.
OK: Battery positive voltage

Q. Is the check result normal?





STEP 8. Check the wiring harness between C-302 dead lock relay connector terminal No.3 and fusible link (38).


note Prior to the wiring harness inspection, check ETACS-ECU connector C-309, and repair if necessary.

  • Check the power supply line for open or short circuit.

Q. Is the check result normal?





STEP 9. Resistance measurement at C-302 dead lock relay connector.


(1)Disconnect the connector, and measure at the wiring harness side.
(2)Continuity between C-302 dead lock relay connector terminal No.2 and body earth
OK: Continuity (less than 2Ω)

Q. Is the check result normal?





STEP 10. Check the wiring harness between C-302 dead lock relay connector terminal No.2 and body earth.



  • Check the earth wires for open circuit.

Q. Is the check result normal?





STEP 11. Retest the system.



Q. Is the check result normal?