Inspection Procedure 9: The multi information display screen cannot be changed with the operation of the multi information meter switch.
| caution | Before replacing the combination meter, be sure to check that the power supply circuit, earth circuit, and communication circuit are normal. |
COMMENTS ON TROUBLE SYMPTOM
PROBABLE CAUSES
- Malfunction of multi information meter switch
- Malfunction of combination meter
- Damaged harness wires and connectors
DIAGNOSIS PROCEDURE |
STEP 1. M.U.T.-III diagnosis code |
| Check if diagnosis code is set to the combination meter. |
Q.
Is the diagnosis code set?
|
Refer to . |
|
Go to Step 2. |
|
STEP 2. Retest the system |
| Check that the multi information display screen switches normally when the multi information meter switch is operated. |
Q.
Is the check result normal?
|
The trouble can be an intermittent malfunction (Refer to GROUP 00 - How to use Troubleshooting/inspection Service Points - How to Cope with Intermittent Malfunction ). |
|
Replace the combination meter. |
|
Refer to 