Inspection Procedure 17: Engine-ECU battery back-up system








OPERATION



  • Backup power source is directly supplied to an engine-ECU from a battery.

PROBABLE CAUSES



  • Damaged harness (Open circuit between engine-ECU and battery)
  • Damaged connector (Engine-ECU connector)
  • Failed engine-ECU

DIAGNOSIS PROCEDURE


STEP 1. Check battery voltage.



  • Measure battery voltage during cranking.
OK: 8 V or more

Q. Is the check result normal?

Go to Step 2 .
Check battery (Refer to GROUP 54A - Battery - On-vehicle Service - Battery test ).

STEP 2. Connector check: D-215 engine-ECU connector


Q. Is the check result normal?

Go to Step 3 .
Repair or replace.

STEP 3. Perform voltage measurement at D-215 engine-ECU connector.



  • Disconnect connector, and measure at harness side.
  • Voltage between terminal No. 103 and earth.
OK: System voltage

Q. Is the check result normal?

Go to Step 4 .
Check intermediate connectors D-111, A-03 <L. H. drive vehicles> or D-137 <R. H. drive vehicles>, and repair if necessary. If intermediate connectors are normal, check and repair harness between D-215 (terminal No. 103) engine-ECU connector and battery.

STEP 4. Check the trouble symptoms.


Q. Does trouble symptom persist?

Replace the engine-ECU. When the engine-ECU is replaced, write the chassis number (Refer to GROUP 00 - Precautions Before Service - How to Perform Chassis Number Writing ). After replacing the engine-ECU, register the injector identification code and learn fuel injection (Refer to GROUP 00 - Precautions Before Service - What The Common Rail Engine Learns ). After registering the injector identification code, the vehicle equipped with the closed type DPF carries out the forcible DPF regeneration. (Refer to GROUP 17 - Diesel Particulate Filter (DPF) System - Forcible DPF Regeneration ).
Intermittent malfunction (Refer to GROUP 00 - How to Use Troubleshooting/Inspection Service Points - How to Cope with Intermittent Malfunction ).