If there is a problem with any of the A/T system, the N range lamp will flash at a rate of approximately once per second. If the N range lamp is flashing at a rate of approximately once per second, check the diagnosis output. N range lamp flashing item
- Input shaft speed sensor system
- Output shaft speed sensor system
- Solenoid valves system
- Non-synchronization at various shift ranges
- A/T control relay system
| note |
If the A/T fluid temperature warning lamp is illuminating, the A/T fluid temperature is high. (It flushes when the fluid is approximately 125°C or more and goes off when the fluid is approximately 115°C or less.)
|
|
|
|
Use the M.U.T.-III to read the diagnosis code. (Refer to GROUP 00 - How to Use Troubleshooting/Inspection Service Points, Diagnosis Function ).
|
|
|
Use the M.U.T.-III to erase the diagnosis code. (Refer to GROUP 00 - How to Use Troubleshooting/Inspection Service Points, Diagnosis Function ).
|
|
|
A/T learned value must be reset whenever the automatic transmission, engine assembly, A/T valve body, or A/T solenoid valve is replaced. It cannot be reset by disconnecting the battery. Use the M.U.T.-III as follows:
|
|
|
1.Shift the selector lever to P and turn the ignition switch to the LOCK (OFF) position.
|
|
|
2.Connect the M.U.T.-III to the vehicle’s diagnosis connector.
|
|
|
3.In the ELC-A/T menu screen, select "Special Function," then select "Memory Reset."
|
|
|
4.Select "OK" to reset the A/T learned memory.
|
|
|
5.After this initialisation, make the system learn the idling in accordance with "Learning procedure for idling in MPI engine" (Refer to GROUP 00 - Precautions before Service, Learning Procedure For Idling in MPI Engine ).
|