Inspection Procedure 1: The security alarm is not armed (The security indicator does not illuminate).



caution Before replacing the ECU, ensure that the power supply circuit, the earth circuit and the communication circuit are normal.












COMMENTS ON TROUBLE SYMPTOM




  • Keyless entry transmitter
  • Key reminder switch
  • Ignition switch (ACC)
  • Hood switch

PROBABLE CAUSES



  • Malfunction of security indicator
  • Malfunction of keyless entry transmitter
  • Malfunction of the key reminder switch
  • Malfunction of hood switch
  • Malfunction of the ETACS-ECU
  • Damaged harness wires and connectors

DIAGNOSIS PROCEDURE


STEP 1. Check the keyless entry transmitter.


Check that the keyless entry system works normally.

Q. Is the check result normal?

Go to Step 2.
Refer to GROUP 42 - keyless Entry System, Troubleshooting .

STEP 2. Customise function by using the SWS monitor.


Use the SWS monitor customisation function to confirm that "Security alarm function" is set to "Horn/Hazard".
caution The SWS monitor must be used in order to confirm and change that setting. Use the SWS monitor to confirm and/or change the customised function.

Q. Is the check result normal?

Go to Step 3.
Use the SWS monitor customisation function to set "Security alarm function" is set to "Horn/Hazard" (Refer to ).

STEP 3. SWS monitor data list


Check the SWS communication input signals, which are related to the security alarm.
<Selected item> ETACS ECU
  • Turn the ignition switch to the ACC position.
Item No.
Item name
Normal condition
Item 31
IG SW(ACC)
ON
OK: Normal condition is displayed.

Q. Is the check result normal?

Go to Step 4.
Refer to Input Signal Chart .

STEP 4. ETACS switch data by using the SWS monitor


Check the ETACS-ECU signals, which are related to the security alarm.

  • Ignition switch: OFF (key inserted)
Item No.
Item name
Normal condition
Item 03
Key reminder switch
OFF
OK: Normal conditions are displayed for all the items.

Q. Is the check result normal?

Go to step 5.
Refer to Input Signal Chart .

STEP 5. Pulse check


Open the closed hood, and check if the buzzer of M.U.T.-III sounds at that time.
OK: The M.U.T.-III sounds or the voltmeter needle fluctuates.

Q. Are the check result normal?

Go to step 6.
Refer to Input Signal Chart .

STEP 6. Connector check: D-40 security indicator connector


Q. Is the check result normal?

Go to step 7.
Repair the defective connector.

STEP 7. Checking the security indicator


Check that the security indicator is normal (Refer to ).

Q. Is the check result normal?

Go to step 8.
Replace the security indicator.

STEP 8. Voltage measurement at the D-40 security indicator connector.


(1)Disconnect the connector, and measure at the wiring harness side.
(2)Voltage between D-40 security indicator connector terminal No.1 and body earth
OK: System voltage

Q. Is the check result normal?

Go to step 10.
Go to step 9.

STEP 9. Check the wiring harness between D-40 security indicator connector terminal No.1 to fusible link (1).


note Prior to the wiring harness inspection, check intermediate connectors D-39 and D-241, and repair if necessary.

  • Check the power supply line for open circuit and short circuit.

Q. Is the check result normal?

The trouble can be an intermittent malfunction (Refer to GROUP 00 - How to Cope with Intermittent Malfunction ).
Repair the wiring harness.

STEP 10. Connector check: D-421 ETACS-ECU connector


Q. Is the check result normal?

Go to step 11.
Repair the defective connector.

STEP 11. Check the wiring harness from D-421 ETACS-ECU connector terminal No. 26 to D-40 security indicator connector terminal No. 2.


note Prior to the wiring harness inspection, check intermediate connector D-39, and repair if necessary.

  • Check the input and output lines for open and short circuit.

Q. Is the check result normal?

Go to step 12.
Repair the wiring harness.

STEP 12. Retest the system.


Check that the security alarm works normally.

Q. Is the check result normal?

The trouble can be an intermittent malfunction (Refer to GROUP 00 - How to Cope with Intermittent Malfunction ).
Replace the ETACS-ECU.