Diagnosis Item 5: Diagnose when the M.U.T.-III cannot receive the data sent by combination meter.



caution When servicing a CAN bus line, earth yourself by touching a metal object such as an unpainted water pipe. If you fail to do, a component connected to the CAN bus line may be broken.












FUNCTION




TROUBLE JUDGEMENT CONDITIONS




PROBABLE CAUSES



  • Damaged harness wires and connectors
  • Power supply circuit malfunction of the combination meter
  • Malfunction of the combination meter

DIAGNOSIS PROCEDURE


STEP 1. Connector check: D-03 joint connector (CAN1) and D-04 combination meter connector


caution The strand end of the twist wire should be within 10 cm from the connector. For details refer to .
When checking the joint connector, ensure that its wiring harness side and its short pins are not damaged.

Q. Is the check result normal?

Go to Step 2.
Repair the defective connector. Replace the joint connector as necessary.

STEP 2. Resistance measurement at D-03 joint connector (CAN1) and D-04 combination meter connector.


caution A digital multimeter should be used. For details refer to .
caution The test wiring harness should be used. For details refer to .
(1)Disconnect joint connector (CAN1) and the combination meter connector, and measure at the wiring harness side.
(2)Turn the ignition switch to the LOCK (OFF) position.
(3)
caution When measuring the resistance, disconnect the negative battery terminal. For details refer to .
Ensure that the negative battery terminal is disconnected.
(4)Continuity between D-03 joint connector (CAN1) terminal No.3 and D-04 combination meter connector terminal No.23 <LHD>
OK: Continuity (2 Ω or less)
(5)Continuity between D-03 joint connector (CAN1) terminal No.14 and D-04 combination meter connector terminal No.24 <LHD>
OK: Continuity (2 Ω or less)
(6)Continuity between D-03 joint connector (CAN1) terminal No.1 and D-04 combination meter connector terminal No.23 <RHD>
OK: Continuity (2 Ω or less)
(7)Continuity between D-03 joint connector (CAN1) terminal No.12 and D-04 combination meter connector terminal No.24 <RHD>
OK: Continuity (2 Ω or less)
caution Strictly observe the specified wiring harness repair procedure. For details refer to .

Q. Is the check result normal?

<All the resistances measure 2 Ω or less> Go to Step 3.
NO : <Either or all of the resistances measures more than 2 Ω> Repair the wiring harness between joint connector (CAN1) and the combination meter connector.

STEP 3. Resistance measurement at D-04 combination meter connector.


caution A digital multimeter should be used. For details refer to .
(1)Remove the combination meter, and measure at the equipment side.
(2)Resistance at D-04 combination meter connector terminal Nos.23 and 24
OK: 120 ± 20 Ω

Q. Is the check result normal?

<Within 120 ± 20 Ω> Power supply to the combination meter may be suspected. Diagnose the combination meter. Refer to GROUP 54A, Combination meter - Symptom procedures .
<Not within 120 ± 20 Ω> Replace the combination meter.