Inspection Procedure 3: The hazard warning lamps do not flash while the security alarm is triggered.
| caution | Whenever the ECU is replaced, ensure that
the input and output signal circuits are normal. |
COMMENTS ON TROUBLE SYMPTOM
PROBABLE CAUSES
- Malfunction of the ETACS-ECU
- Damaged harness wires and connectors
DIAGNOSIS PROCEDURE
STEP 1. Check that the hazard warning lights operate.
Q.
Is the check result normal?



STEP 2. Customise function by using the SWS monitor.
| caution | The SWS monitor must be used in order to confirm and change
that setting. Use the SWS monitor to confirm and/or change the customised function. |
Q.
Is the check result normal?



STEP 3. Retest the system.
Q.
Is the check result normal?